ASSOCIATED RESEARCH 3665 CALIBRATION and ASSOCIATED RESEARCH 3665 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ASSOCIATED RESEARCH 3665 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   ASSOCIATED RESEARCH 3665   Description / Specification:    
ASSOCIATED RESEARCH 3665 5kV AC, 6kV DC Hipot with Ground Continuity Check

The Associated Research 3665 5KV AC, 6KV DC Hipot with Ground Continuity Check has an enhanced Graphic LCD and entry-level automation with an RS-232 interface. Features. Remote Safety Interlock feature prevents the high-voltage from being activated without the interlock enabled. Electronic Ramp and Dwell timers for more consistent and reliable testing. Interconnects with an Associated Research Ground Bond tester to form a complete test system. Digitally controlled arc detection circuit allows the operator to program sensitivity levels for detecting arcs. Minimum and maximum trip settings for safer and more accurate testing. Specifications. Dielectric Withstand Test Mode Output Rating: 5000 V @ 20 mA AC, 6000 V @ 7.5 mA DC. Voltage Setting Range: 0 - 5.00 KV AC, 0 - 6.00 KV DC. Voltage Setting Resolution: 0.01 KV. Voltage Setting Accuracy: ± (2% of setting + 5 V). Maximum Limit AC Range: 0.00 - 20.00 mA, Resolution 0.01 mA. Maximum Limit DC Range: 0 - 7500 µA, Resolution 1 µA. Maximum Limit Accuracy: AC and DC ± (2% of setting + 2 counts). AC Voltage Waveform: Sine Wave, Crest Factor = 1.3 - 1.5, <2% THD. Output Frequency Range: 50 or 60 HZ, User Selectable. Ground Continuity Current: DC 0.1 A ± 0.01 A, fixed.



 

Standard Calibration $405.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ASSOCIATED RESEARCH 3665. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Channel Bandwidth
Channel Bandwidth is the bandwidth over which power is measured. This is usually the bandwidth in which almost all of the power of a signal is contained.

Jitter
Jitter in technical terms is the deviation in or displacement of some aspect of the pulses in a high-frequency digital signal. Jitter is the time variation of a periodic signal in electronics and telecommunications, often in relation to a reference clock source. Jitter may be observed in characteristics such as the frequency of successive pulses, the signal amplitude, or phase of periodic signals. Jitter is a significant, and usually undesired, factor in the design of almost all communications links (e.g., USB, PCI-e, SATA, OC-48). In clock recovery applications it is called timing jitter.

Overshoot
Overshoot is the distortion that follows a major transition; the difference between the peak power point and the pulse-top amplitude computed as a percentage of the pulse-top amplitude.

Rise Time
Rise time refers to the time required for a signal to change from a specified low value to a specified high value, usually 10 and 90 percent of pulse-top amplitude (vertical display is linear power).


Please contact us for your ASSOCIATED RESEARCH 3665 CALIBRATION and/or ASSOCIATED RESEARCH 3665 5kV AC, 6kV DC Hipot with Ground Continuity Check REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: